DSpace Repository

Influencia de la tasa de enfriamiento en la resistencia a corrosión de la aleación Ti6Al4V eli deformada en caliente

Show simple item record

dc.contributor.author Córdoba, L.C. es
dc.contributor.author Maya, S. es
dc.date Julio - Diciembre es
dc.date.accessioned 2015-06-19T19:13:55Z
dc.date.available 2015-06-19T19:13:55Z
dc.date.issued 2009
dc.identifier.issn 1692-8261
dc.identifier.uri http://hdl.handle.net/11619/1352
dc.description.abstract Este artículo pretende hacer un aporte específico relacionado con la posibilidad de obtener mediante forja en caliente componentes de Ti6Al4V ELI con la microestructura y propiedades aptas para aplicaciones biomédicas. Las muestras fueron sometidas inicialmente a un proceso de forja en caliente a dos niveles de temperatura seleccionadas dentro del intervalo bifásico de la aleación. Se empleó una velocidad de avance de la herramienta de 1.8 cm/s y tres medios de enfriamiento, agua, aire y arcilla, con el fin de determinar su influencia sobre la microestructura y la resistencia a corrosión. Para el análisis microestructural se emplearon las técnicas de microscopía óptica de luz reflejada (MOLR) y microscopia electrónica de barrido (MEB). La resistencia a corrosión de la aleación fue evaluada mediante curvas de polarización cíclica en solución Ringer desaireada a temperatura corporal (37°C). Los resultados de resistencia a corrosión de las muestras deformadas fueron confrontados con los de la condición en el estado de entrega comercial, lo que permitió concluir sobre las condiciones de procesamiento del material con el fin de implementar un procedimiento adecuado de forja en caliente a nivel industrial para su uso como biomaterial. es
dc.description.abstract Abstract: The aim of this paper is to discuss the feasibility of manufacturing Ti6Al4V ELI components with proper microstructure and mechanical properties for biomedical applications. The samples were hot forged at two temperature levels, both of them within the dual phase field (α + β). A constant strain rate of 4x10-3 s-1 was employed. The samples were cooled in three different cooling media (water, air and clay) and some correlations between cooling rate and microstructure and corrosion resistance were established. The microstructure was analyzed with the aid of light optical microscopy (LOM) and scanning electron microscopy (SEM) techniques. The corrosion resistance was determined by cyclic polarization tests in Ringer´s solution at 37°C. Comparison between the results obtained for forged and commercial samples allowed concluding about some of the recommended manufacturing conditions of Ti6Al4V for biomedical applications. en
dc.language.iso es es
dc.publisher Universidad Autónoma del Caribe es
dc.relation.ispartofseries Vol. 7 No. 2 Pág. 95-101
dc.subject Aleación Ti6Al4V ELI es
dc.subject Microestructura es
dc.subject Resistencia a Corrosión es
dc.subject Procesos Termomecánicos es
dc.subject ELI grade Ti6Al4V alloy es
dc.subject Microstructure es
dc.subject Corrosion Resistance es
dc.subject Thermomechanic Processes es
dc.title Influencia de la tasa de enfriamiento en la resistencia a corrosión de la aleación Ti6Al4V eli deformada en caliente es
dc.title.alternative Influence of the rate of cooling in the resistance to corrosion of the alloy Ti6Al4V eli deformed in warms es
dc.type Article es


Files in this item

This item appears in the following Collection(s)

  • Prospectiva [220]
    Revista de la Facultad de Ingeniería

Show simple item record