<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns="http://purl.org/rss/1.0/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dc="http://purl.org/dc/elements/1.1/">
<channel rdf:about="http://hdl.handle.net/1/627">
<title>Programa de Ingeniería Mecánica</title>
<link>http://hdl.handle.net/1/627</link>
<description/>
<items>
<rdf:Seq>
<rdf:li rdf:resource="http://hdl.handle.net/11619/1873"/>
<rdf:li rdf:resource="http://hdl.handle.net/11619/817"/>
<rdf:li rdf:resource="http://hdl.handle.net/11619/816"/>
<rdf:li rdf:resource="http://hdl.handle.net/11619/815"/>
</rdf:Seq>
</items>
<dc:date>2026-04-05T15:43:16Z</dc:date>
</channel>
<item rdf:about="http://hdl.handle.net/11619/1873">
<title>Instalación de extractores eólicos en viviendas residenciales de distintos estratos sociales para disminución de carga térmica.</title>
<link>http://hdl.handle.net/11619/1873</link>
<description>Instalación de extractores eólicos en viviendas residenciales de distintos estratos sociales para disminución de carga térmica.
Náder Insignares, Rachid Salim; Rada Sarmiento, Miguel Osvaldo
Hoy en día, con el constante cambio climático que hay en el mundo, se ven&#13;
reflejadas las altas y bajas temperaturas que se presentan, pero más allá haciendo&#13;
referencia a la actual ola de calor que se está viviendo en general, se plantea la&#13;
idea de presentar un proyecto con el fin de minimizar la temperatura y humedad&#13;
de los hogares. Conociéndose la necesidad de las personas por reducir las altas&#13;
temperaturas que se presentan en distintas zonas tropicales y llegar a la zona de&#13;
confort, se sabe que los sistemas de refrigeración de aire acondicionado y los&#13;
ventiladores son los más usados en los hogares, lo que resulta una pérdida de&#13;
dinero en costos energéticos alrededor de $ 397.56 pesos por kwh consumido&#13;
para estrato 6 y $ 197.88 pesos por kWh para los estrato 1, ya que al utilizar estos&#13;
equipos en el día por varias horas para mejorar las condiciones de temperatura en&#13;
el recinto consumirán energía eléctrica y elevaran los costos energéticos de las&#13;
viviendas. Además del mantenimiento para un uso eficiente del mismo, fuera de&#13;
las inversiones comunes que son la compra y la instalación del mismo en caso&#13;
que lo requiera. Cada vez es más común hablar de ventilación y climatización en el hogar para con esto disminuir la sensación de calor y sudoración. La ventilación en el hogar cumple diferentes funciones, no solo renueva el aire interior, elimina malos olores,&#13;
gases y humo sino que también reduce la temperatura interior en el recinto, es por&#13;
esto que se hace la necesidad de estudiar la posibilidad de disminución de&#13;
temperatura y humedad en el hogar implementando los ventiladores o extractores&#13;
eólicos.
</description>
<dc:date>2013-01-01T00:00:00Z</dc:date>
</item>
<item rdf:about="http://hdl.handle.net/11619/817">
<title>Caracterización del desempeño de los refrigerantes R134a y R22 estudiados en el laboratorio de plantas térmicas de la Universidad Autónoma Del Caribe.</title>
<link>http://hdl.handle.net/11619/817</link>
<description>Caracterización del desempeño de los refrigerantes R134a y R22 estudiados en el laboratorio de plantas térmicas de la Universidad Autónoma Del Caribe.
Caballero Charris, Jorge Iván; Morales Bonilla, Andrés Felipe
Los sistemas de refrigeración a lo largo de su existencia le han brindado infinidad de soluciones al ser humano, desde la conservación de alimentos hasta la climatización de un recinto para llegar a un estado de confort térmico, sin embargo los refrigerantes que se han utilizado hasta hace unos pocos años han venido degradando el entorno de una manera u otra. El problema que deseamos resolver específicamente es como en Colombia se prohibirá el R22 para dentro de 5 años, hacer un estudio mediante pruebas experimentales para tomar una conclusión si el R134a puede sustituirlo, y que consecuencias tendría en la eficiencia de las maquinas que estamos utilizando, es decir bajo qué condiciones de uso el refrigerante R134a sería una buena alternativa de reemplazo para el R22. La metodología para desarrollar este experimento es tomar los niveles máximos de la presión de alta, en base al correcto funcionamiento del equipo, indicado por los pre experimentos, de flujos de agua en los evaporadores y condensadores respectivos. En este caso se debe experimentar con el equipo hasta tener una diferencia de temperatura en el condensador y el evaporador de agua, que pueda apreciarse sin problemas y que se estabilice en sus valores, esto sucede desde la apertura a nivel medio de las válvulas de flujo de agua para evaporador y condensador. De esta manera el equipo funciona a régimen máximo con el refrigerante (máxima presión, máximo caudal), resultando los valores que corresponden a las diversas variables de respuesta medidas por el software. Al obtener los resultados se ha dado cuenta que para el caso del análisis comparativo, puede decirse que para uso de refrigeración, la sustitución del R22 por el R134a puede hacerse, esperando un manejo menor de la carga térmica manejada, por lo que debe evaluarse cada aplicación.; Abstract: Cooling systems throughout its existence have given you a host of solutions to the human being from food preservation to the climate of a room to reach a state of thermal comfort, however refrigerants have been used until recently a few years they have to degrade the environment in one way or another. The problem we want to solve is as in Colombia specifically R22 to within 5 years will be banned, a study by experimental evidence to make a conclusion whether the R134a can replace it, and what consequences would have on the efficiency of the machines we are using, ie under what conditions of use R134a be a good alternative replacement for the R22. The methodology for developing this experiment is to take the maximum pressure levels high, based on the correct operation of the equipment indicated by the pre experiments, water flows in the evaporators and respective capacitors. In this case you should experiment with the team until a temperature difference in the condenser and evaporator water that can be seen without problems and to stabilize at their values, this happens from the opening to mid-level flow valves water for evaporator and condenser. In this way the equipment operates at maximum speed with coolant (maximum pressure, maximum flow) resulting values corresponding to the different response variables measured by the software. To obtain the results has noticed that in the case of the comparative analysis, use can be said that for cooling, the substitution of R22 with R134a may be waiting a lower thermal management of cargo handled, so it must be evaluated each application. The cooling effect decreased by 6% for the conditions imposed in testing, but also for the use of R134a is under high pressure values, which helps lower power consumption, assuming that the cooling reduction tolerated.
</description>
<dc:date>2014-01-01T00:00:00Z</dc:date>
</item>
<item rdf:about="http://hdl.handle.net/11619/816">
<title>Diseño de un horno para cocción de ladrillos refractarios en una empresa del sector ladrillero</title>
<link>http://hdl.handle.net/11619/816</link>
<description>Diseño de un horno para cocción de ladrillos refractarios en una empresa del sector ladrillero
Fontalvo Porras, Emmanuel De Jesús; Gutíerrez Robles, Eliver José
En este proyecto se propone una solución de diseño para un horno que se piensa utilizar en un proceso de cocción de ladrillos tecnificado. El horno actual es de tipo artesanal, operando con leña, trabajando de manera discontinua, durante máximo cuatro veces al mes, con lotes de 4000 ladrillos cada uno, para un total bruto mensual de 16.000, valor que desea aumentarse. Con el esquema de diseño propuesto se pretende subir la producción a 40.000 ladrillos al mes, operando con gas natural, manteniendo un consumo similar al actual al aprovechar los calores que normalmente se pierden en este tipo de procesos, con los benéficos de triplicar la producción, mejorar la calidad y bajar el impacto ambiental, al disminuir las emisiones de CO2 a la atmosfera. La metodología que se implementa es de tipo descriptiva, organizando el desarrollo del proyecto, con una fase inicial de definición de requerimientos, seguida de una fase de diseño conceptual y de detalle, finalizando con un estimado del presupuesto necesario para materializar el proyecto, aunado a un estimado de rentabilidad del mismo. Con los resultados de este proyecto, se espera que se disminuyan los tiempos de ciclo por unidad, mejorando la productividad y confiabilidad del proceso de cocción de los ladrillos.
</description>
<dc:date>2014-01-01T00:00:00Z</dc:date>
</item>
<item rdf:about="http://hdl.handle.net/11619/815">
<title>Caracterización experimental del equipo TCEC para el estudio de los fenómenos de ebullición y condensación del laboratorio de plantas térmica /</title>
<link>http://hdl.handle.net/11619/815</link>
<description>Caracterización experimental del equipo TCEC para el estudio de los fenómenos de ebullición y condensación del laboratorio de plantas térmica /
Martínez Salazar, William Fernando
Se plantea la evaluación experimental del estudio de los diferentes fenómenos que se presentan en este proceso, es por esto que esta investigación tiene como propósito realizar un análisis de caracterización del equipo para estudio de los fenómenos de ebullición y condensación, ubicado en el laboratorio de plantas térmicas, para conocer los rangos operativos, variables, parámetros y funcionamiento en relación a los fenómenos estudiados, Para cumplir con los objetivos propuestos en este proyecto es necesario tener en cuenta el desarrollo de muestreo de valores a los diferentes parámetros y limitar otros resultados, de esta manera esta investigación se realizara de tipo teórico, práctico y cuantitativo. Por otra parte se aplicara un estudio descriptivo y comparativo ya que la solución final del problema será definir sus características operacionales de este equipo “TCEC” mediante la caracterización experimental y basándose en los resultados obtenidos del estudio de estos. Por otra parte el montaje de las pruebas fue acordado aplicando las normas de seguridad, ya que es la parte principal para realizar dichos ensayos. En este documento se encuentra una guía en el cual se muestran los pasos a seguir para realizar este tipo de pruebas basados en experimentos ya realizados.
</description>
<dc:date>2014-01-01T00:00:00Z</dc:date>
</item>
</rdf:RDF>
